⚡ Elevate your testing game with precision and style!
The AST Labs Test Lead Kelvin Clip to 4-channel Banana Plug features 3-foot 18 AWG silicone wires with gold-plated 4 mm banana plugs and black/red Kelvin clips. Designed for high-precision measurements in automotive, aerospace, and telecom applications, these leads offer flexibility and corrosion resistance but are incompatible with shielded LCR meters like the DE-5000.
| ASIN | B01H4GZP8E |
| Batteries Included? | No |
| Batteries Required? | No |
| Best Sellers Rank | #181,166 in Industrial & Scientific ( See Top 100 in Industrial & Scientific ) #741 in Test Probes & Leads |
| Brand | AST Labs |
| Color | black |
| Customer Reviews | 4.4 4.4 out of 5 stars (53) |
| Date First Available | June 16, 2016 |
| Is Discontinued By Manufacturer | No |
| Item Package Quantity | 1 |
| Item Weight | 6 ounces |
| Item model number | 999-A-007 |
| Manufacturer | AST Labs |
| Material | Gold-plated copper |
| Measurement System | Metric |
| Measurement Type | LCR Meter |
| Number Of Pieces | 2 |
| Package Dimensions | 5.71 x 4.06 x 1.1 inches |
| Part Number | 999-A-007 |
| Style | Industrial |
| UPC | 635323790668 |
J**E
Nice leads and clips!!
Really nice, both the cables and clips. The problem I had with these while modding them for the DE-5000 is that there are no shields! I couldn't get them to pass the open calibration. After doing some research I found that shields are not needed. I decided to cut a foot off of all 4 cables from the meter end and resolder them to the DE-5000. This worked like a charm, calibrates with no problems now. These are extremely flexible cables and I put heat shrink every 6 inches on the red cables and the black cable, then used bigger heat shrink on all 4 wires. It really makes them less messy. These leads turn a great meter like the DE-5000 into an awesome meter!!
K**H
Good product
Little pricey, but these Kelvin clips are VERY well made. I have an older set of Kelvin clips from someone else that are not nearly as good.
S**H
These Work Well But Need Some Tweaking
Bought these for doing 4-wire Ohms with multiple Fluke 884X-series DMMs. All four of the banana plugs were very difficult to insert into the jacks on all of the meters. From the scuff marks on the shrouds it appears the outside diameter of the middle third of the shrouds is slightly too large and causes binding. Cutting back the shrouds to half their original length eliminated enough of the binding to make the leads usable. Other than this mechanical issue, they work fine and are well worth the money. Note: there was no binding when these were used with Fluke 115/117 DMMs. YMMV with other equipment.
A**Y
Works great with Rigol DM3068
Not only do they work well, the build quality is pretty nice. They kind of looked crappy to me in the photos but they're nice to work with. Good clamping force, yet very thin tip allowing you to connect to smaller things than you'd expect. What a bargain! That's a bargain for me. I think I will buy some.
B**D
4 wire measurement
Quickly received and worked well. seem to be of reasonable quality. Would buy again
P**Y
Plug Shroud too fat to fit in Fluke 8840a
They work well enough for my needs, but the banana plug shroud is too fat to go into the front or rear ports on a Fluke 8840a without getting stuck. The only way I was able to get a measurement was by stacking them into banana jacks that do fit.
A**L
Good design
Good design
B**Z
Excellent probes, probably going to buy another
These probes are great. I have been using them with my Fluke 8842A. I did have to use a knife to shave a little bit of the plastic off the outer surface of the probe plugs. They are too thick to fit into most CATIII sockets. I won't deduct any stars for this. The probes work really well and are small enough at the tip that they are useful for almost any general purpose probing, aside from using them for measuring at IC pins (especially SOIC or TSSOP). It is clear that these function well as kelvin probes. I can measure 0.1 and 0.01ohm resistors with these and am relatively confident in the result. The values don't jump around like they do with 2-lead probes.
Trustpilot