🔧 Power Your Projects with Precision!
The OONO Forward and Reverse Relay Module is a versatile and efficient solution for controlling reversing motors and linear actuators. With a rated current of 10 Amps and an operating voltage of 10-15V DC, this compact module features both momentary and alternate action switches, LED status indicators, and energy-saving capabilities, making it ideal for a wide range of applications.
A**R
Consult electrical expert.
Had to play with wiring, to get the relay to work with, rocker up & down switch.
D**.
As advertised
It works. Used on a small window fan project.
G**E
Dependable and long lasting
works well for low amp applications. I am using it to move ainear actuator. it has been working well for the past year
J**R
Works great so far... some measured parameters here
Works great so far. Using it in a project with a digital timer to open and close chicken coop doors.Here are some values I measured, which may save someone time figuring it out themselves.Conditions: Room temperature and 12 VDC power supply.Disclaimer 1: Accurate test equipment was not on-hand, so these are all approximate values.Disclaimer 2: Your device may not be exactly the same as mine. Manufacturer may change the design at any time, I'm sure.Standby power supply current: 0 A when both FWD & REV inputs tied to +12 V or left disconnectedSupply current with FWD or REV input tied to 0 V (ground): 32 mAFWD or REV input threshold voltage that turns ON the M1/M2 outputs: +5.8 V or below (@ 17.7 mA)FWD or REV input threshold voltage that turns OFF the turned-on M1/M2 outputs: +8.2 V or above (@11.7 mA)FWD or REV input current when tied to ground: 31.5 mAFWD or REV input current when tied to +12 V: Immeasurably smallFWD or REV input equivalent resistance: 350 Ω +/- 50 Ω (not directly measurable with ohmmeter, but each input behaves like this resistance when unit is powered)Module clicks when turned on/off, so it seems to contain an electromechanical relayOperation if FWD & REV inputs simultaneously tied to ground: No motor output drive & no LED lit, so this is probably not a recommended operating modeThe two 0 V (ground) lines are internally connected
J**T
It works
Little buggy but it does work. I’ll give a re-update after a few weeks
A**W
Works like it should.
Works like it should.
B**1
Works
Works as expected
J**D
Dead on arrival.
Supplied 12v to the relay, and activated the momentary switches. Relay led never came on, never closed and allowed power out.Will return. Trash.